For single crowns and short bridges, not in any way that matters. A review of the studies found no significant difference in how well ceramic crowns fit at the edge after a digital scan or a mould; in patients the average gap was 56 microns after a scan and 79 microns after a mould, both a small fraction of a millimetre (Tsirogiannis 2016). Long bridges and full-arch implant bridges are different: guidelines say scanners match moulds for single crowns and short bridges but have limits for spans of more than four teeth and for jaws without teeth (Ruhstorfer 2026). Most people find scanning more comfortable (Gallardo 2018). The real bonus of a scan is the file: you can take it home, a lab can work from it again, and a dentist in Australia can open it.

  • Average edge gap in patients: 56.1 microns after a digital scan, 79.2 microns after a mould, no significant difference (Tsirogiannis 2016).
  • Scanners match moulds for single crowns and short bridges, with limits for spans of more than four teeth (German S2k guideline, Ruhstorfer 2026).
  • Four of five studies found digital scans more comfortable, with less anxiety and gagging (Gallardo 2018).

Scan or mould, at a glance

Digital scanTraditional mould
How it is doneA small camera wand is moved over the teeth and builds a 3D model on screenA tray of soft material sits in the mouth for a few minutes and sets; the lab pours a plaster model
Fit of single crownsAs good as a mould in the reviews (Tsirogiannis 2016)The long-standing benchmark
Short implant bridgesFit comparable to a mould in a randomised trial (Derksen 2021)Comparable
Long bridges and full archesHas limits; depends on the method (Ruhstorfer 2026)Often still the more reliable method for long spans (Li 2026)
ComfortUsually preferred, with less gagging (Gallardo 2018)Bulky tray, taste, gagging for some
What you can keepA digital file you can copy and sendA plaster model, which stays with the lab
Redoing itCan rescan one areaThe whole mould is usually redone

The short version: for one crown or a few, the method does not decide the fit. The care at each step does: a clean, visible edge on the trimmed tooth, a good scan or mould of it, and a good lab. For a full arch on implants, ask how the clinic checks the fit, because there the method matters more.

What each method actually is

After the tooth is trimmed for a crown, the lab needs an exact copy of it, of the teeth next to it and of the teeth it bites against. That copy is the impression.

  • A traditional mould uses a soft silicone-type material in a tray. It sets in a few minutes in your mouth. The lab pours plaster into it to make a model and builds or designs the crown on that model.
  • A digital scan uses an intraoral scanner, a wand with a camera at the tip. It takes thousands of images and joins them into a 3D model. The file goes straight to the lab, which designs the crown on screen and mills or prints it.
  • Many labs now work digitally either way. A mould can be poured and then scanned in the lab, so the final crown is designed on a computer whichever way the copy was taken.

Both methods need the same groundwork. The edge of the trimmed tooth, often just under the gum, must be clean, dry and visible. A thin cord is often placed in the gum for a few minutes to open the space. If the edge cannot be seen, neither a scanner nor a mould can copy it.

Does a scan change how well crowns fit?

Fit is usually measured at the edge of the crown, where it meets the tooth. There is always a tiny gap there, filled with cement. A smaller gap means less cement exposed to the mouth and less space for decay to start. The gap is measured in microns: 1,000 microns make one millimetre.

StudiesAfter a digital scanAfter a mouldDifference
Studies in patients (Tsirogiannis 2016)56.1 microns79.2 micronsNot significant
Lab studies (Tsirogiannis 2016)63.3 microns58.9 micronsNot significant

A review of 12 studies found no significant difference in edge fit between ceramic single crowns made from scans and from moulds (Tsirogiannis 2016). Another review found digital impressions gave similar or slightly better fit, mostly in lab studies, and noted that plaster models added the largest errors (Chochlidakis 2016). Either way, the gaps were well under a tenth of a millimetre.

Implant crowns and short implant bridges show the same picture. In a randomised trial of 45 screw-retained zirconia bridges on two implants, the fit with a scan was comparable to the fit with a mould. Adjustment took 6.92 minutes on average for the scanned bridges and 12.38 minutes for the moulded ones, a difference that was not statistically clear (Derksen 2021).

So for crowns, choose the clinic for its care and its lab, not for its scanner.

Long bridges and full arches: where scanners still have limits

A scanner builds the model by joining many small images. Over a short distance the small errors stay small. Over a whole arch they can add up, and a full arch with no teeth has few landmarks for the scanner to follow.

  • A 2026 German guideline, agreed by 29 dental societies, found scanners comparable to moulds for single crowns and short bridges, but with limits for bridges of more than four units and for jaws with many or all teeth missing (Ruhstorfer 2026).
  • A 2026 review of full-arch implant scans found that a plain scan was more accurate than a mould over short implant spans but less accurate over long spans. Newer methods that correct the joining errors looked more accurate than moulds, but the evidence is still limited (Li 2026).
  • International implant experts noted that for jaws without teeth, the result of scanning depends on the method followed (Wismeijer 2018).

This matters for All-on-4 and other full-arch bridges. The bridge joins several implants in one rigid piece, so it has to sit on all of them at once without strain. Clinics handle this in different ways: a mould with the implant parts joined together, a scan with special scan aids, or a check of the fit with a trial frame before the final bridge is made. Ask which one the clinic uses.

Comfort, gagging and time in the chair

Most people prefer the scanner. A review of studies on patient views found that in four of five studies, scanning was more comfortable and caused less anxiety and less feeling of sickness. Time was mixed: two studies found moulds quicker and three found scans quicker (Gallardo 2018).

  • A strong gag reflex is a good reason to ask for a scan. There is no tray full of material at the back of the mouth, and the dentist can stop and restart at any time.
  • A scan can be repeated in one small area. If a mould has a bubble at the key spot, the whole mould is usually taken again.
  • Scans are not always quicker. Scanning a full mouth carefully, including the bite, takes time too.

Our page on a strong gag reflex covers what helps with impressions, crowns and implants.

What a scan file lets you do

This is where scanning is most useful for someone who flies home after treatment.

  • Take it home. The file can be sent by email or a download link. A dentist in Australia can open a standard scan file and see exactly what was made.
  • Send it ahead. If you already have a recent scan, a clinic can see your teeth before you fly.
  • A remake from the same file. If a crown breaks but the tooth under it has not changed, a lab can often make a new one from the original scan, without a new impression. If the tooth or gum has changed, a new scan is needed.
  • Track changes. Scans taken over time can be laid over each other to show wear, gum changes or tooth movement (Ruhstorfer 2026).
  • A night guard. A lab can design a guard from your final scan, so you do not need another mould at home.

A traditional mould gives you none of this. The plaster model stays with the lab.

What scanners cannot do yet

  • Most scanners record only how your teeth meet when you bite together, not how they slide when you chew or grind. Extra steps are needed to record those movements (Ruhstorfer 2026).
  • Blood or saliva at the edge of the tooth hides it from the scanner, just as it spoils a mould.
  • Edges deep under the gum are harder for a camera to see than for a mould to reach.
  • The result depends on the operator and the method (Ruhstorfer 2026). A good scanner used carelessly gives a poor copy.

Which method suits my case? Choice by situation

Your situationUsual methodWhy
One to a few crownsEither; scan is commonFit is the same in the reviews (Tsirogiannis 2016)
A full set of crowns or veneersEither, often a scan in sectionsEach crown is separate; the bite record matters most
A short bridgeEitherComparable for short spans (Ruhstorfer 2026)
A long bridge of more than four unitsOften a mould, or a scan with extra checksScanners have limits over long spans (Ruhstorfer 2026)
A single implant crownScan with a scan body, or a mouldComparable fit
All-on-4 or a full-arch bridgeA method chosen for full arches, plus a fit checkErrors can add up over the whole arch (Li 2026)
A strong gag reflexScanNo tray in the mouth (Gallardo 2018)

Asking for your scan files

Ask for your files before you leave the clinic. They belong in your records, like your X-rays and your implant card.

  1. The scan of your teeth before treatment, if one was taken.
  2. The scan of the trimmed teeth that the crowns were made from.
  3. The scan of your teeth with the final crowns in place, if the clinic takes one.
  4. For implants: the 3D X-ray scan files, and the scan of the implant positions.
  5. Ask for standard file types. Tooth scans are usually STL or PLY files; 3D X-ray scans are usually DICOM files.
  6. Ask for a download link or a USB stick, and check that the files open before you fly home.

What this means for a crown trip from Australia

  • The impression method does not change the trip. Crowns need one trip of up to 7 days.
  • If you have a scan from your dentist at home, send the file before you fly. It helps with planning, although a new scan is taken once teeth are trimmed.
  • On fitting day, the crown is checked in your mouth whatever the method: the edge, the contact with the next tooth and the bite.
  • Leave with the files. If a crown ever needs replacing, they save time and help a dentist at home.

How much do crowns cost in Vietnam?

BrandPer tooth16 teeth20 teethLab warranty
Standard
KatanaJapanA$222A$3,560A$4,4407 years
CeramillAustriaA$286A$4,580A$5,72010 years
DD BioGermanyA$333A$5,330A$6,66010 years
Plus
Origin Beyond PlusUSAA$357A$5,720A$7,14010 years
Lava PlusUSAA$444A$7,110A$8,88015 years
Lava EstheticUSAA$554A$8,870A$11,08015 years
Premium
Orodent BleachItalyA$666A$10,050A$12,56019 years
Origin ApexUSAA$971A$15,540A$19,42015 years

Updated Nov 2026

Free flight
& hotel
Claim now
T&Cs apply

Zirconia crowns at our partner clinics in Vietnam cost A$222 to A$971 per tooth, depending on the brand: the lowest to the highest price on the list above. The scan or mould is part of making the crown. Ask the clinic to confirm that your quote includes it.

Questions to ask the clinic

  1. Will you take a scan or a mould for my crowns, and why?
  2. For my full-arch bridge, which method do you use, and how do you check the fit before the final bridge?
  3. Can you scan me if I gag with trays?
  4. How will you record my bite?
  5. Can I have my scan files, in STL or PLY, before I leave?
  6. If a crown breaks later, can the lab remake it from the file?

Common beliefs that are not quite right

  • "Digital crowns fit better." For single crowns, the fit is the same in the reviews (Tsirogiannis 2016).
  • "Moulds are outdated." For long bridges and some full-arch work, a mould can still be the more reliable choice (Li 2026).
  • "A scan means no gum cord or no fuss." The tooth edge still has to be clean and visible, whichever method is used.
  • "With a scan file, a crown can always be remade without seeing a dentist." Only if the tooth has not changed. A new crown still has to be fitted by a dentist.
  • "The scanner makes the crown." A person designs it and a lab makes it. The scan is only the copy.

How does The Hudson help?

The Hudson is not a clinic. We are a small team in Hanoi. We audit every clinic we work with and pick the one we trust most for each case. We ask the clinic how your crowns or bridge will be copied and checked, tell them in advance if you have a strong gag reflex, and make sure you leave with your scan files and X-rays. Someone from our team comes to every appointment with you, including the fitting.

How we make money

You don't pay us anything. When you go ahead with treatment, the clinic pays us a referral fee for each patient. It doesn't change your price: you pay the clinic's normal price, the same as if you walked in yourself.

Quick answers

Are digital impressions more accurate than moulds?

For single crowns, about the same: a review found no significant difference in edge fit (Tsirogiannis 2016). For long bridges and full arches, moulds can still be more reliable (Li 2026).

Do crowns from a digital scan fit better?

Not in a way that matters. In patients, the average edge gap was 56 microns after a scan and 79 microns after a mould, not a significant difference (Tsirogiannis 2016).

Is a digital scan better for a gag reflex?

Usually yes. Most studies found scanning more comfortable, with less anxiety and less feeling of sickness (Gallardo 2018).

Can I get a copy of my dental scan?

Yes, ask for it. Tooth scans are usually STL or PLY files and 3D X-rays DICOM files. Check that they open before you fly home.

Is a scan accurate enough for All-on-4?

It depends on the method. Plain scans have limits over a whole arch, so ask how the clinic copies the implant positions and checks the fit before the final bridge (Ruhstorfer 2026).

Have a scan from your dentist at home?

Send us the file with your X-rays. We pass them to the dentist at a partner clinic in Vietnam, who looks at your teeth before you book. Free.